SVM5H-250H MCCB de 1000 V CA

SVM5H-250H  1000VAC MCCB(images 1)

General

SVM5H series of moulded case circuit breaker is supplied with rated insulating voltage 1150V and used for circuit of A.C. 50Hz, rated operating voltage AC 1140V. (or below), rated operating current up to 630A for infrequent changing over and starting of the motors.

Products are widely used in new energy, photovoltaic (string type), electric power, industrial control, real estate, power supply, telecommunications, rail transit and other industries.

Equiped with the protection devices for over-current, short circuit and u ndervoltage, the products are capable of preventing damage of circuits and supply units. The products conforms to GB/T14048.2, IEC60947-2 stardands.

Normal Operating Conditions                                            

Altitude: ≤2000m  

Installation height 2000m ~ 5000m can be specially customized. The product needs to reduce the capacity to use.

Pollution Degree: 3 according to IEC 60947-1

Ambient Temp. (operating): -5 to 40 ℃

For the working conditions of -40~-5℃ ambient temperature, please inform us when ordering.

When the ambient temperature is higher than 40 ° C, the product should be used at reduced capacity.

Ambient Temp. (storage): -40 to 70 ℃

The average ambient temp. in 24 hours cannot exceed 35 ℃.

The relative humidity cannot exceed 50% @+40 ℃. A lower temperature can have a higher humidity. The relative humidity can reach 90% at 20 ℃, and corresponding measures should be taken for the condensation frost caused by the temperature change.

Model Description of MCCB

SVM5H-250H  1000VAC MCCB(images 2)

Characteristics                                                            

Poles3P
Frequency50 Hz
Rated Current (In)63, 80, 100, 125, 180, 225, 250
Rated Insulation Voltage Vi1150 V AC
Rated Impulse Withstand Voltage (Uimp)8kV
Rated Operational Voltage (Ue)AC800VAC1000/1140V
Breaking Capacity CodeH
Limiting Short-circuit Breaking Capacity Icu36.5kA15kA
Operating Short-circuit Breaking Capacity Ics36.5kA15kA
Mechanical Life20000 cycles
Electrical Life3000 cycles2000 cycles
Temperatura ambiente-35℃~+70℃
AccessoryShunt release, auxiliary device, alarm device, manual operating mechanism, electric operating mechanism
Dimensions (L*W*H)180*107*126mm
ÚLTIMO: SIGUIENTE:

Recomendaciones relacionadas

  • NDM2E-400

    1071

    1. Applicable Scope and Purpose of Circuit Breaker The NDM2E-400 series of electronic molded case circuit breakers (hereinafter referred to as circuit breakers) apply to infrequent switching of circuits with the AC 50Hz, the working voltage of A...

    Ver detalles
  • Estabilizador automático de tensión AVR

    222

    Regulación automática de tensión para equipos que requieren un suministro estable de baja tensión en condiciones de fluctuación de la red eléctrica. El estabilizador automático de tensión (AVR) corrige continuamente las variaciones de la tensión de alimentación para proporcionar una salida más estable a los equipos conectados...

    Ver detalles
  • NDGR2-63 Isolating Switch

    1300

    Applications: NDGR2-63 isolating switch fuse group applied to ac 50 hz, rated voltage of AC400V, AC690V, rated current 63 a low-voltage distribution network, or motor as infrequently connected, breaking circuit and circuit isolation. Available ...

    Ver detalles
¡Más información!

Lista de productos de consulta
Lista de productos de consulta Enviar una consulta sobre los productos anteriores