Especificaciones:

Electrical Features
ModeElectromagnetic
Type (wave form of the earth leakage sensed)B
Rated Current In25, 40, 63A
Poles2P, 4P
Rated Voltage Ue2P 240V~, 4P 415V~
Insulation Voltage Ui500V
Rated Frequency50/60Hz
Rated Residual Operation Current (In)30mA
Rated Residual Operating Current (Idc)6mA
Rated Residual Making & Breaking Capacity (Im)500A (In≤40A), 10In (In>40A)
Short-circuit Current Inc = Ic10000A
SCPD FuseRCCB SVL1M-63(images 2)
Break Time Under In≤0.1s
Rated Impulse Withstand Voltage (1.5/50) Uimp4000V
Dielectric Test Voltage at ind.Freq. for 1min2.5kV
Electrical Life2000 Cycles
Mechanical Life4000 Cycles
 
Instalación
Contact Position IndicatorYes
Protection DegreeIP20
Ambient Temperature (with daily average≤35)-25℃~+35℃
Storage Temperature-25℃~+70℃
Terminal Connection TypeCable/Pin-type Busbar/U-type Busbar
Terminal Size top/bottom for Cable35mm2  18~3AWG
Terminal Size top/bottom for Busbar35mm2  18~3AWG
Tightening Torque2.5Nm  22In-lbs
MountingOn DIN Rail EN60715(35mm) by means of fast clip device
ConnectionPower Supply in Both Directions

Tripping Current Range:

Lagging AngleI△n>0.01AI△n≤0.01A
0.35I△n ≤ I△ ≤ 1.4I△n0.35I△n ≤ I△ ≤ 2I△n
90°0.25I△n ≤ I△ ≤ 1.4I△n0.25I△n ≤ I△ ≤ 2I△n
135°0.11I△n ≤ I△ ≤ 1.4I△n0.11I△n ≤ I△ ≤ 2I△n
 
Alternative Current SensitivePulsating Direct Current SensitiveSurge Current Proof
B Class
Tripping is ensured for sinusoidal AC residual currents pulsed DC residual current, alternating residual sinusoidal currents up to 1000Hz, pulsating direct residual currents and for smooth direct residual currents, whether applied suddenly or increasing slowly.
RCCB SVL1M-63(images 3)
They react to AC and pulsating DC fault current which reach 0 or almost 0 within one time period of the mains frequency.
RCCB SVL1M-63(images 4)
RCCB’s surge capacity. Not tripping at standardized 8/20 us surge-current waves acc.to VDE 0432 Part 2 with surge current values of up to 250A.

Overall and Installation Dimension (mm) 

RCCB SVL1M-63(images 5)

Circuit Diagram

RCCB SVL1M-63(images 6)
ÚLTIMO: SIGUIENTE:

Recomendaciones relacionadas

  • NDQ3-400

    1101

    1. Applicable Scope and Purpose The NDQ3-400 P-grade ATSE are applicable for sites with the AC voltage below AC380V.AC400V.AC415V and the rated frequency of 50Hz. This product complies with the GB14048.1-2012 and GB/T14048.11-2016 standards i...

    Ver detalles
  • Interruptor automático de caja moldeada NDM5-1600H

    1156

    The NDM5-1600 series of moulded case circuit breakers (referred to as circuit breakers) have a rated insulation voltage of 1000V and apply to circuits with the AC 50Hz/60Hz, the rated working voltageAC380/400/415V、AC500V、AC660/690V、AC800V,Va...

    Ver detalles
  • Estabilizador automático de tensión AVR

    222

    Regulación automática de tensión para equipos que requieren un suministro estable de baja tensión en condiciones de fluctuación de la red eléctrica. El estabilizador automático de tensión (AVR) corrige continuamente las variaciones de la tensión de alimentación para proporcionar una salida más estable a los equipos conectados...

    Ver detalles
  • NDB2-63 MCB miniature circuit breaker

    875

    1.Application scope and purpose 2.Main technical specification Product certification and implementation standard: Environmental requirements: RoHS Isolation function 3.Normal working environment: 4.Packing storage:

    Ver detalles
¡Más información!

Lista de productos de consulta
Lista de productos de consulta Enviar una consulta sobre los productos anteriores